Home
Solutions
Decarbonization & Renewable Energy

Microinverter

Efficient power conversion for PV

Mi-SURIA (Solar PVMS)

Optimize solar farm performance

Axis Tracker

Maximize sunlight exposure

BESS

Reliable energy storage solutions

PMSM Motor

High-performance electric motors

Mi-ACE

Advanced control electronics

CREAM Initiative

Sustainable energy practices

AI & Smart Building Management

Mi-VAM

Secure visitor management

MAIRA (Facial Rec)

Advanced facial recognition security

Integrated Facilities Management

Holistic building control

Mi-AIBox

Secure & private AI solutions

Intelligent Plantation & IoT

Inspectra

Non-destructive crop analysis

UGV Navigation

Autonomous ground vehicle guidance

Insights
U

Search here

Home > Case Study > KPJ Ampang Puteri

KPJ Ampang Puteri

Overview

KPJ Ampang Specialist Hospital is a major private healthcare facility operating 24 hours a day, 365 days a year. The hospital runs a 1,100 RT installed chiller capacity (550 RT on duty) by Trane, serving comfort cooling across clinical wards, operating theatres, laboratories, and public areas. The operating environment imposes strict requirements: temperature must be held between 20–25°C, relative humidity maintained at 40–65% across general areas, and certain zones such as operating theatres and labs require stricter control at 35–60% humidity to prevent fungal infection risk. MSSB deployed Mi-ACE in June 2017, making KPJ Ampang one of the earliest and longest-tenured Mi-ACE installations in the healthcare sector. The deployment demonstrates that AI-driven chiller optimisation can operate reliably within the most stringent building environment requirements in any industry.

Performance

• Year 1: Staged savings approach to 6% average annual savings achieved safely
• Year 2: Savings grew to 6–8% as system learned facility demand patterns
• Year 3 onwards: Reached and sustained >10% savings consistently
• YTD Savings Average (lifetime): 12.3%
• Critical operating conditions maintained throughout: Operating theatres and labs held at 35–60% RH for infection prevention compliance
• System has operated continuously since June 2017 as one of MSSB's longest active deployments

Building Type

Commercial

Application Type

Comfort Cooling

Chiller Manufacturer

Trane

Installed Capacity

1100 RT
550 RT Duty

Date System Installed

June, 2017

YTD Savings Average

12.3%

Temperature

20-25°C

Operating Hour

12 Hours

Humidity

40-65% with certain areas at 35-60%

24/7 hospital chiller optimisation maintaining clinical-grade environmental control

Result

Total MWh Saved Annually

104.99 MWh

Total CO2e Emission Saved

72.86 Tonne CO₂e

Total Trees Equivalent Saved

1,228.38 Trees

Annual Cost Savings

RM 132,067

Average Energy Savings

12.3%

Deployment Tenure

Since June 2017 (7+ years active)